Cage and suite services - separate protection of the racks
Individualized rack housing
Our physically separate cages and suites provide you with enclosed IT environments at our data centers that keep your racks even more secure, including a reliable power supply, natural cooling system and a TÜV-audited security system. You can have the security package tailored to your specific requirements at our ISO-certified data centers.
For cages please note: Capacity service for a cage (with a number of mainrack or maincustomerrack) in a datacenter area, minimum number of racks of 8 and an average power density of at least 5kW/Rack (FRA01) or 3kW/Rack (AMS01)
Product comparison in tabular form:
- SLA availability of power and air conditioningSLA availability of power and air conditioning
- Basic servicesBasic services
- Up to 10 personalized, permanent access cardsUp to 10 personalized, permanent access cards
- power and air conditioning (provision)power and air conditioning (provision)
- access to the data centeraccess to the data center
- receipt of delivery of goodsreceipt of delivery of goods
- disposal of wastedisposal of waste
- fire protectionfire protection
- monitoring and reportingmonitoring and reporting
- maintenance and repair servicemaintenance and repair service
- Service-Desk and Service-PortalService-Desk and Service-Portal
- Cage or suite serviceCage or suite service
- separation by cageseparation by cage
- constructional separationconstructional separation
- Card reader with integration into the access control systemCard reader with integration into the access control system
- mutually agreed rack planningmutually agreed rack planning
- Capacity in kw as the sum of the rack capacities in kwCapacity in kw as the sum of the rack capacities in kw
- available for mainrackavailable for mainrack
- available for maincustomerrackavailable for maincustomerrack
- power connections according to cage / suite capacity (A/B)power connections according to cage / suite capacity (A/B)
- connection to cable trays for network cabling to cage / suiteconnection to cable trays for network cabling to cage / suite
- power usage servicepower usage service
- Option: Security-Plus against surchargeOption: Security-Plus against surcharge
- additional vein scanneradditional vein scanner
- video surveillance of the cage doorvideo surveillance of the cage door
- protection against climbing over and crawling underneathprotection against climbing over and crawling underneath
- separation unitseparation unit
- additional procedural security, individual operating manualadditional procedural security, individual operating manual
- access control by trust centeraccess control by trust center
maincage
- SLA availability of power and air conditioning100%
- Basic services
- Up to 10 personalized, permanent access cards
- power and air conditioning (provision)
- access to the data center
- receipt of delivery of goods
- disposal of waste
- fire protection
- monitoring and reporting
- maintenance and repair service
- Service-Desk and Service-Portal
- Cage or suite service
- separation by cage
- constructional separation
- Card reader with integration into the access control systemoption
- mutually agreed rack planning
- Capacity in kw as the sum of the rack capacities in kw
- available for mainrack
- available for maincustomerrack
- power connections according to cage / suite capacity (A/B)
- connection to cable trays for network cabling to cage / suite
- power usage service
- Option: Security-Plus against surcharge
- additional vein scanner
- video surveillance of the cage door
- protection against climbing over and crawling underneath
- separation unit
- additional procedural security, individual operating manual
- access control by trust center
mainsuite
- SLA availability of power and air conditioning100%
- Basic services
- Up to 10 personalized, permanent access cards
- power and air conditioning (provision)
- access to the data center
- receipt of delivery of goods
- disposal of waste
- fire protection
- monitoring and reporting
- maintenance and repair service
- Service-Desk and Service-Portal
- Cage or suite service
- separation by cageoption
- constructional separation
- Card reader with integration into the access control system
- mutually agreed rack planning
- Capacity in kw as the sum of the rack capacities in kw
- available for mainrack
- available for maincustomerrack
- power connections according to cage / suite capacity (A/B)
- connection to cable trays for network cabling to cage / suite
- power usage service
- Option: Security-Plus against surcharge
- additional vein scannerstandard in FRA01
- video surveillance of the cage door
- protection against climbing over and crawling underneath
- separation unitstandard in FRA01
- additional procedural security, individual operating manual
- access control by trust center