Perfect Performance and Sustainable Waste Heat Utilization

With our FRA02 data center, maincubes is setting new standards in efficiency and sustainability. Through innovative cooling technology, we ensure optimal temperature control, resulting in higher performance and longer server life. At the same time, we consistently rely on green power, thus actively contributing to the reduction of CO₂ emissions. What makes this data center special, is the use of waste heat. This means that the waste heat generated during server cooling is efficiently used to heat buildings in the local community or reused for other purposes in the heating network. This reduces heating costs and promotes a sustainable use of resources.

Another special feature of FRA02 is that it meets very high operational requirements. The server rooms are individually built according to previously agreed customer requirements. In this way, we provide the agility to create maximum flexibility to meet customers’ desired power and density.

We have already successfully leased the data center to a customer who is part of the German government and are very proud of the trust placed in us. Together with this user, we are making an important contribution to sustainability, while at the same time meeting the very high operational requirements.

Are you interested in our services? Feel free to contact us.

Secure capacity DOWNLOAD FACT SHEET

8

MW

IT Capacity

54000

ft²

Whitespace

≤ 1,3

Design PUE

100

%

SLA Availability

Map-FRA02

Firmly Rooted in the Rhine-Main Region

Frankfurt FRA02 – located in the heart of the Rhine-Main economic region, committed to sustainability, and deeply rooted in the local community.

FRA02 at a Glance

IT area: 5,000 m² / 54,000 ft²
IT capacity: 8 MW
100 % availability
High Performance Computing possible
Energy efficiency value (PUE) below 1,3
Cooling approach utilizing outdoor air
Fire protection with early detection and automatic gas extinguishing system
Freight elevator (2,5 t)
Possibility of waste heat recovery
FRA02 will be supplied exclusively with green electricity
ISO 27001:2022
ISO 9001:2015
DIN-EN 50600 incl. VK3
ÖkoPLUS certified
Carrier-neutral

All information can be found here for DOWNLOAD.

CERTIFICATIONS

oekoplus-certification-climateneutral
Smart-Greening-Oekostrom-Logo
gutcert_ISO_14001
gutcert_ISO_50001
emas_maincubes-de
tuv-maincubes-MS-9001
tuv-maincubes-MS-27001
Soc2-Typ2-zerti
ISAE3402-Soc1-zerti

All Advantages of Our Data Center at a Glance

maincubes-ausfallsicherheit

Reliability

FRA02 is certified according to DIN-EN50600 VK3. It does exceed these requirements in the area of power supply and thus achieves availability class IV (VK4) in parts. maincubes relies on rotating UPS systems in the IP bus for an uninterruptible power supply.

maincubes-energieeffizienz

Energy-Efficient Cooling

Efficient, open-air cooling is a central pillar of the FRA02 design. The cool wall technology relies on large-area, water-flow heat exchanger modules for air conditioning. The air-conditioning concept already includes pre-equipment for server water cooling and immersion cooling.

maincubes_abwaermenutzung

Waste Heat Recovery

The waste heat from FRA02 is efficiently fed into the municipal heating network to sustainably heat buildings in the surrounding area. By doing so maincubes optimises the use of resources and provides a sustainable heat supply for the community.

maincubes-physische-sicherheit

Physical Security

Our data center offers multi-layer security from the outside gate to your own space in the data center. Clients or maincubes can provide what is required – from biometrics to multi-level access controls, camera surveillance, comprehensive fire protection and a 24-hour, on-site security service. Customised IT infrastructure security installations meet every customer need without construction constraints.

maincubes-single-tenant-colocation

Single-Tenant Colocation

FRA02 is a single-tenant data center. This means that there is only one user of the colocation, whose needs are met by the networks, power supply and physical security. Thanks to the flexible design, maincubes was able to meet all of its customer’s requirements.

maincubes-architektur-und-design

Architecture and Design

By deliberately integrating this into our data centers, we ensure that our data center is not only a place of technology, but also part of the local character and history. FRA02 has been designed with environmental considerations in mind resulting in a harmonious interplay between functionality and aesthetics.

Contact

Please Feel Free to Send Us Your Inquiry

Jobs

Find Digital Technology Trends Exciting?

Design your career at maincubes and become part of our team!

Learn More